By Dr. Maxime Ndayizeye
BQUALI LLC (Atlanta)
A certification audit rarely fails because a procedure is missing. It fails because the procedure and the plant have drifted apart. Internal audits are supposed to catch that drift, but too often they review the binder and miss the finding an SQF or BRCGS auditor will raise a few weeks later.
Here are five common gaps at food manufacturing sites, why internal audits miss them, and a check you can run before your next audit. Clauses refer to the SQF Food Safety Code: Food Manufacturing, Edition 9, and the BRCGS Global Standard for Food Safety, Issue 9. Confirm the edition that applies to your site.
1. Corrective actions closed without root cause or a check that the fix worked
A non-conformance is written up. Someone retrains the operator or attaches a photo of a cleaned area, and the action is marked closed. Weeks later the same issue returns, or a certification auditor asks for the root cause and the evidence that the fix worked, and there is nothing behind the signature. Internal auditors miss this when they only check that the form was completed on time.
How to catch it
Pull the last 10 closed corrective actions, including complaints and previous audit findings. For each one, ask:
- Is there a documented root cause, or only a correction (cleaned it, retrained, replaced the part)?
- If the cause is “operator error” or “retraining,” what allowed the error, and what changed in the system?
- Who verified effectiveness, how, and after how long? Recurrence means the original action was not effective.
This is SQF clause 2.5.3 (Corrective and Preventative Action, mandatory) and BRCGS clause 3.7 (a fundamental). Both require root cause analysis and verification that the action was implemented and is effective. BRCGS also requires a responsible person and timescales.
2. Records that do not match what happens on the floor
The CCP check sheet is complete and every pre-operational item is marked acceptable. Then you walk the line and the thermometer in use is not the one on the form, or operators describe a different method than the work instruction. Internal audits miss this when they stay in the office. Paperwork can show that records exist. It cannot show that they are true.
How to catch it
For every process you audit, take records from the shift in progress and walk the floor with them in hand. Ask the person doing the work to show you the task, then compare it with the procedure and the form. Look for checks signed before the work could have been done, identical values copied down a column, equipment or forms that do not match what is in use, and operators who cannot explain a step they just signed for.
This is SQF clause 2.2.3 (Records, mandatory) and clause 2.5.4 (Internal Audits and Inspections, mandatory), which requires objective evidence, not just a checklist score. In BRCGS it sits in clause 3.3 (record completion and maintenance) and clause 3.4 (Internal audits, a fundamental), which also requires objective evidence of conformity and non-conformity.
3. Environmental monitoring results that are never trended
The site swabs and files the results. A positive triggers a reclean and a resampling, which comes back negative, and the event is closed. No one plots the data, so no one sees that the same drain or Zone 3 site has been creeping toward a limit for months. Internal auditors miss this when they only confirm that a program exists and that last week’s results are on file. The finding is not “no program.” It is no review of trends.
How to catch it
Ask for the last 6 to 12 months of results, not last week’s swabs. Check whether they are reviewed by site, zone, and organism (Listeria species or Listeria monocytogenes, Salmonella, and your indicator organisms). Were repeat or nearby positives investigated as a trend, with vector swabbing and a true root cause, or only recleaned until the next swab was negative? If results have been negative for a long time, challenge the program: always-negative data can mean the wrong sites, time, or organism.
SQF clause 2.4.8 requires a risk-based environmental monitoring program and, at 2.4.8.3, trending of results with preventive action on unsatisfactory trends. BRCGS clause 4.11.8 requires the same kind of program, action on failed limits or an upward trend of positives (4.11.8.2), and at least an annual review, including when results are consistently negative (4.11.8.3).
4. Training records without proof of competence
The training matrix is current and the attendance sheets are signed. Then a CCP monitor cannot describe the critical limit, or the action to take when it is not met, in a way that matches the food safety plan. Temporary or agency staff may already be on the line. Internal auditors miss this when they equate a signature with competence. Both codes ask for more than attendance: evidence that the person can do the task.
How to catch it
Do not stop at the matrix. Sample CCP monitors, allergen changeover staff, environmental swabbers, and temporary staff on the current shift. Watch them do the task, or ask them to walk you through it, including what they do when something is wrong. Find the competency verification on the record, not only the attendance signature: who assessed them, how, and when? Confirm that agency and new staff were trained before they started work.
SQF clause 2.9.2 (Training Program, mandatory) requires defined competencies, and records must include verification that the trainee is competent (2.9.2.3). BRCGS clause 7.1 (Training, a fundamental) requires personnel who affect product safety, legality, and quality to be demonstrably competent, with competency assessment for critical control points (7.1.2) and routine review of competencies (7.1.3 and 7.1.7).
5. Allergen changeovers signed off without a real verification
The schedule shows a change from an allergen-containing run to a product that does not contain that allergen. The changeover form is signed. Cleaning may have been validated once, years ago, with no recent verification, no test of the cleaned surface, and no check that the right labels were staged after the clean. Internal auditors miss this when they look for a completed form instead of evidence that the clean worked. An allergen failure can become a recall.
How to catch it
Reconstruct the last allergen changeover on a high-risk line, and watch one if a changeover is scheduled during your audit. Was the method the validated method, or an informal shortcut? What verified that the allergen was removed: a visual check only, or a test defined in your validation, such as an allergen-specific swab? Were labels, packaging, rework, and utensils controlled so the previous allergen could not re-enter the line? Can the operators who signed the form explain their steps?
SQF clause 2.8.1 (Allergen Management, mandatory) requires effective changeover cleaning, with documented validation and verification and documented changeover procedures (2.8.1.4 to 2.8.1.6). BRCGS clause 5.3 (Management of allergens, a fundamental) requires controls to prevent cross-contact (5.3.4) and cleaning that is validated and routinely verified (5.3.8).
A short pre-audit checklist
Use this list before your next SQF or BRCGS audit, or as a standing habit for every internal audit:
- Sample closed corrective actions. Confirm root cause, the action taken, and a later check that the fix worked.
- Audit live work with the day’s records in hand. A complete form is not proof that the work was done as written.
- Trend environmental results for at least the last six months. Treat repeat or rising positives as a system issue, not a one-off reclean.
- Test competence on the floor. A signed training matrix is not enough.
- Reconstruct a recent allergen changeover. Include the validated method, routine verification, and label and packaging control.
- Give the same scrutiny to suppliers and calibration. Look for expired supplier documents, skipped certificates of analysis, emergency receipts from unapproved suppliers, and devices in use that are overdue, missing from the calibration register, or out of tolerance with no review of affected product (SQF 2.3.4 and 11.2.3; BRCGS 3.5.1 and 6.4).
If your internal auditors only review documents, they will keep missing these findings. The skill is knowing what to sample, what to ask, and when to leave the office.
Build those skills in BQUALI’s Internal Auditor training
BQUALI’s live virtual Internal Auditor training is built for QA and food safety teams who audit against GFSI-benchmarked schemes, including SQF and BRCGS. The course covers planning an audit, gathering objective evidence on the floor, writing findings, and following corrective actions through root cause and effectiveness checks.
Upcoming dates:
- December 22–23, 2026
- January 14–15, 2027
- February 23–24, 2027
Classes run 9 AM–5 PM EST (New York). The fee is $900. See the schedule and register on the Internal Auditor training page.